Disclaimer

The photographs, images, drawings or sketches shown in this advertisement/promotional material represent an artist's impression of the development concerned only. They are not drawn to scale and/or may have been edited and processed with computerized imaging techniques and are provided for reference purposes only. The color and all the fittings, finishes, equipment, layout, decoration, design, plants, landscaping, ornaments and facilities shown in the layout plan are for reference only and may not be appeared in the Development or nearby. They do not constitute and shall not be interpreted to constitute any offer, commitment, statement, or warranty whatsoever, whether express or implied and subject to the provision upon the date of occupation. The vendor also advises agents and prospective purchasers to conduct an on-site visit for a better understanding of the development site, its surrounding environment and the public facilities nearby.

Under the Government Lease and the approved building plans of the Development, the Development shall not be used for any purpose other than for industrial purposes. According to the Lands Department, permissible uses of a lot restricted for "industrial" purpose must involve a process of manufacturing and take place within the lot. The Vendor advises prospective purchaser to seek professional advice on permitted user of the Development. No warranty is given by the vendor on any other use of the Development and the purchaser shall conduct its own independent research and decide.

The Vendor reserves the right to amend the building plans and other plans of the Development from time to time. The design, detail plans and all information regarding areas of the Development is subject to the final plans approved by the relevant Government authorities. All layout, interior and exterior design, fittings and finishes and all provisions and usage as shown in this advertisement are subject to the final adjustment upon completion and do not constitute and shall not be interpreted to constitute any offer, commitment, statement or warranty whatsoever, whether express or implied, and subject to the final approval by the relevant Government authorities.

Date of Last Update: 20 September 2024

Enter > 简体

Hand-Over Standard

Floor-to-Floor Height

G/F: Approximately 4.9 meters

1/F: Approximately 7.3 meters

2/F to 28/F: Approximately 4.825 meters

Power Supply

G/F: 300A TPN each workshop

1/F: 300A TPN each workshop

2/F: 160A TPN each workshop

3/F to 28/F: 63A TPN each workshop

Floor Loading

5.0 kPa

Air Conditioning‭

VRV System

Communications Equipment

Various telecommunication and broadband companies available

Independent communication cable system

Installed with receivers receiving local digital TV, public TV, and radio channels

External Wall‭ ‬

Curtain wall system with reflective‭ / ‬tinted glass and aluminum cladding

Glazed ceramic tiles

Entrance Foyer

Wall‭: ‬Marble tiles‭, ‬stainless steel‭, ‬glass‭, ‬wood veneer finish‭, ‬plastic laminate finish

Floor‭: ‬G/F - Marble‭; ‬1‭/‬F Marble

Ceiling‭: ‬G/F escalator lobby - Gypsum board false ceiling finished with emulsion paint‭; ‬1/F - Gypsum board false ceiling finished with emulsion paint

Typical Lift Lobby

Wall‭: ‬Stainless steel‭, ‬plastic laminate finish‭, ‬mirror

Floor‭: ‬Stone pattern porcelain tile

Ceiling‭:  Gypsum board false ceiling finished with emulsion paint‭, ‬Aluminium baffle ceiling

Workshop

Internal Wall‭: ‬Finished with cement‭ / ‬lime plaster‭ & ‬emulsion paint

Internal Floor‭: ‬Cement sand screeding

Internal Ceiling‭: ‬Finished with emulsion paint‭ ‬

Male Lavatory‭ /  ‬Female Lavatory‭ / ‬Accessible Lavatory

Wall‭: ‬Finished with porcelain tiles‭, ‬plastic laminate finish

Floor‭: ‬Finished with porcelain tiles

Ceiling‭: ‬Gypsum board false ceiling finished with emulsion paint and installed with light fittings

Fittings‭: ‬Air-conditioning and high quality sanitary wares

Disclaimer

Floor-to-floor height: The height difference between the top of the floor slab of a floor and the top of the floor slab of the upper floor (including the thickness of the floor slab of the upper floor). According to the floor, partition and architectural structure of individual units, each unit has different floor heights, and there may be different floor heights within the same unit.

All photos, images, illustrations, perspective drawings, or sketches in this advertisement/promotional material only represent an artist’s impression. They are not shown to scale and may be edited and processed with computerized imaging techniques, and they are not photos of actual scenes. It is recommended that prospective purchasers visit the development site for on-site inspections to understand better the development site, its surrounding environment, and nearby public facilities.According to the conditions in the Land Grant, the property is limited to general industrial use. After the purchaser has obtained approval from the relevant government department (but not limited to the Lands Department), the purchaser can use the land for other non-residential uses. The Director of Lands may approve other non-residential uses from time to time. The vendor and its agents do not guarantee that the property is appropriate for other non-residential use and do not guarantee that the purchaser can obtain approval from the relevant government department. The purchaser should conduct independent research and judgment.